Analysis and Maesurements

Analysis and measurements 368 Conductivity meters h6 conductivity measurement ranges h7 resistivity measurement ranges from 0.1 Ω.cm to 100.0 MΩ.cm hUSP Compliant ‹ 645 › for purified water and injectable preparations hGLP compliance: storage of the last calibration data in the digital probe hAutomatic recognition of the probe per instrument hAdjustable temperature coefficient hAutomatic calibration of up to 5 points hPowered by 4 x 1.5 V batteries hIP67 hInternal memory: 400 measurements on demand, 1000 in automatic memory hTransfer to a PC via micro USB port (software required) Supplied with: • case with 4-ring conductivity probe HI763133; • with DIN connector and 1 m cable; • standard solutions 1413 µS/cm (230 ml) and 111.8 mS/cm (230 ml); • 2 x 100 ml plastic beakers; • data transfer software, mini USB cable and batteries. EC Range 0.001 to 9.999 µS/cm*; 10.00 to 99.99 µS/cm; 100.0 to 999.9 µs/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm Accuracy ± 1 % of measured value (±0.01 µS/cm or 1 digit (whichever is greater)) Calibration Automatic up to 5 points with 7 standard buffers stored (0.00 µS/cm; 84 µS/cm; 1413 µS/cm; 5 mS/cm; 12.88 mS/cm; 80 mS/cm; 111.8 mS/cm) Temperature Range - 20 to 120 °C Resolution 0.1 °C Accuracy ± 0.2 °C (excluding sensor error) Temperature correction Without correction, linear (-20 to + 120 °C), non-linear (0 to 36 °C)-ISO/DIN 7888 Measurement mode Automatic selection, selection at final value, selection of range set at measured value and manual range selection by user Reference temperature 15 °C; 20 °C; 25 °C Temperature coefficient 0.00 to 10.00 %/ °C Cat. No. 523702 € N/A - Accessories Cat.No Description € 523706 Conductivity probe HI 763133 N/A - 052018 Solution 84 µS/cm (500 ml) N/A - 052019 Solution 1413 µS/cm (500 ml) N/A - 052020 Solution 12880 µS/cm (500 ml) N/A - 052021 Solution 80000 µS/cm (500 ml) N/A - 052022 Solution 111800 µS/cm (500 ml) N/A - * The conductivity range 0.001 µS/cm and resistivity 0.1 MΩ.cm cannot be measured with probes with a 4 m cable. hLarge graphic display hDirt-resistant touch keyboard hContextual help menu hAutomatic 4-point calibration for high accuracy h4 ring platinum conductivity probe with replatinisation function hTemperature coefficient adjustable from 0 to 10% hAutomatic or manual storage of measurements hUSB port for connection to a computer hGLP compliance Delivered with: • Conductivity probe HI 76312, • Calibration solutions 1413 µS/cm, 5000 µS/cm and 12880 µS/cm, • rinsing solutions, • electrode holder, • AC adapter. Conductivity Range 0.000 to 1000 mS/cm Resolution From 0.001 µS/cm to 1 mS/cm Accuracy ± 1% Resistivity Range 1.00 Ohm-cm to 100.0 MOhm-cm Resolution From 0.01 Ohm-cm to 0.1 MOhm-cm Accuracy ± 2 % TDS Range 0.000 mg/l at 400.0 g/l Resolution From 0.001 mg/l to 0.1 g/l Accuracy ± 1 % Salinity Range Practical salinity: 0.00 to 42.00 g/l Sea water: 0.00 to 80.00 g/l NaCl %: 0.0 to 400.0 % Resolution Practical salinity: 0.01 g/l Sea water: 0.01 g/l NaCl %: 0.1 % Accuracy ± 1 % Temperature Range - 20 to 120 °C Resolution 0.1 °C Accuracy ± 0.2 °C Memorization Up to 10 batches and 5000 measurements per batch PC connection Optically isolated USB port Dim. W x D x H (mm) 160 x 231 x 94 Weight (kg) 1.2 Cat. No. 052410B € N/A - Hanna HI 98192 conductivity meter HI 5321 Research Quality Conductivity Meter See full technical specifications at www.dulis.nl WEB

RkJQdWJsaXNoZXIy MTUwNzIy