Equipment

Equipment 1388 hTemperature range ambient +5ºC to 130ºC, 4-digit display of block temperature hWith rapid heat-up time hSold without block: to be completed with one, two or four interchangeable blocks (see page 1389) hSafety: protection against overheating hTimer 1 to 999 minutes and delayed start up to 72 hours hOptional covering lid h2 calibration points hWarranty: 3 years hExcellent transparency: very good visibility hProtection against accidents (splashes, hot blocks) hSuitable for QBD and QBH2 models Cat. No. 144335 Cover for QBD1 N/A - 144336 Cover for QBD2 and QBH2 N/A - 144337 Cover for QBD4 N/A - Description € External temperature sensor Temperature control of the block or sample. Stainless steel rod size 3 x 30 mm. 35 cm of cable. Cat. No. 144338 External temperature sensor N/A - Description € Cover 144337 on heating block 144333 Grant-Bio Dry baths / heating blocks Polycarbonate safety covers Model QBH2 Temperature range ( °C) Ambient +5 °C to 200 °C Working selection ( °C) 15 °C to 200 °C Stability at 37 °C ( °C) +/- 0.1 Uniformity in the block ( °C) +/- 0.1 Inter-block uniformity ( °C) +/- 0.2 Temperature rise from ambient to maximum 15 minutes Display resolution ( °C) 0.1 Dimensions L x D x H (mm) 200 x 280 x 100 Power (W) 300 Cat. No. 144334 € N/A - Model QBD1 QBD2 QBD4 Block capacity 1 2 4 Temperature range ( °C) Amb. +5 °C to 130 °C Amb. +5 °C to 130 °C Amb. +5 °C to 130 °C Temperature selection ( °C) 15 °C to 130 °C 15 °C to 130 °C 15 °C to 130 °C Stability at 37 °C ( °C) +/- 0.1 +/- 0.1 +/- 0.1 Uniformity in the block ( °C) +/- 0.1 +/- 0.1 +/- 0.1 Inter-block uniformity ( °C) +/- 0.2 +/- 0.2 +/- 0.2 Temp. rise from 25 °C to 100 °C 20 minutes 20 minutes 20 minutes Display resolution ( °C) 0.1 0.1 0.1 Dimensions L x D x H (mm) 200 x 230 x 100 200 x 280 x 100 200 x 380 x 100 Power QBT1 / 2 /4 (W) 150 300 600 Cat. No. 144331 144332 144333 € N/A - N/A - N/A - hDesigned specifically for molecular biology applications hCompact design, takes up little bench space hOperates from 5 °C above ambient temperature to 200 °C hTimer 1 to 999 minutes and delayed start up to 72 hours h2 calibration points hWarranty: 3 years Temperature range ( °C) Ambient +5 °C to 100 °C Temperature selection ( °C) +25 °C to +100 °C Stability à 37 °C ( °C) / Uniformity ( °C) +/- 0.1 / +/- 0.1 Voltage (V) 220 - 240 V Dimensions L x D x H (mm) 210 x 230 x 110 Block: ø x depth (mm) 130 x 45 Power (W) 200 Overheating protection Fuse Cat. No. 144327 € N/A - hDigital display hWith circular fixed block hFor 49 samples: 24 x 1.5/2 ml microtubes, 15 x 0.5 ml microtubes, 10 x 0.2 ml microtubes hTimer programmable from 1 minute to 96 hours hFast heat-up from 25 °C to 37 °C in 4 minutes and from 25 °C to 100 °C in 15 minutes hSafety: IEC61010 compliant Grant-Bio BTD Digital Dry Block Heater for Microtubes Grant-Bio QBD Digital Dry Block Heater Grant-Bio QBH2 Digital Dry Block Heater for molecular biology hSold without blocks: to be completed with interchangeable blocks (see page 1389): - 144315 for 0.2 ml, strips or microplates; - 144316 0.5 ml microtubes; - 144317 1.5 ml microtubes.

RkJQdWJsaXNoZXIy MTUwNzIy